Loading...

SMART Digital Dosing Pump – Top Features

SMART WATER

Every Drop. SMART Control

Supports analog, pulse, and Modbus communication, and works with relays and sensors for input/output.

High-precision DOSING

With the integrated fast suction slow discharge technology, achieving 1% accuracy in full range capacity.

Water Drop
Slow Mode Graph scaled
2Gen Touch

User-friendly Interface

Implementing smart digital controller, with clear information displayed and easy to operate.

FLEXIBLE Installation

The portable controller supports three different orientations, allowing user to install in complex environments.

2Gen Remote 1
2Gen Pump Head

Full PTFE Diaphragm

Upgraded full PTFE diaphragm. Extended service life and upgradeable to diaphragm rupture sensing with alarm.

Chemical RESISTANT

Various pump head material such as PVC/PVDF/SS316L to handle all corrosive chemicals.

ML Pump Head
calibration scaled

Multiple CALIBRATION mode

A simple one step calibration mode, additional features for calibrating analog signals and fine tune of output flow rate.

General WIRING Port

No need of special cables for connectivity. Easy and straight forward.

2Gen Wiring
Water splash pump

IP65 Rating

Both the drive unit and control unit are sealed within an IP65-rated enclosure, providing better protection.

OMNIcompatible

WRS’s new digital pump technology is able to apply to other series such as hydraulic diaphragm and piston dosing pumps.

Hydraulic SMART

Optional for Plus /  Lite Series

gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==

Front Side Heading

Front side content Front side content Front side content Front side content Front side content Front side content

Back Side Heading

THIS PUMP SIBEH POWERFUL

Your Content Goes Here

Your Content Goes Here

Your Content Goes Here

Your Content Goes Here
Category Description PLUS LITE
Control Panel
Display/Control Mode HMI Touch Screen — Flexible 3 locations for controller placement.
LCD with buttons — Fixed location for controller placement.
Homepage information display Real-time flow rate + set flow rate
Flow rate percentage
External connection signals (pressure/level)
Current pump status/warnings
Password Protection Prevent unauthorized personnel from altering pump settings.
Operation Mode
Manual Users manually enter the target flow rate.
Pulse Input pulse signal, measured in milliliters per pulse.
Analog 4-20mA Standard Analog 4-20mA — Pump flow rate changes according to the analog input signal.
Positive Analog Scaling — Flow rate changes positively with signal input: at 4 mA the pump operates at minimum flow rate Q1; as current increases to 20 mA, flow rate increases linearly to Q2.
Negative Analog Scaling — Flow rate changes inversely with signal input: at 4 mA the pump operates at maximum flow rate Q1; as current increases to 20 mA, flow rate decreases linearly to Q2. 20-4mA
Pulse Based Batch Pump is started and stopped by input pulse signals. Unit in pulse.
Cycle Mode Users may add a specified amount at designated time points in a cycle and repeat.
Bus Communication Modbus RTU – RS485, user able to set device code and baud rate.
Others
Flowrate Calibration Calibrate pump actual capacity according to the pumping fluid.
External On/Off Pause & start pump via external on/off signal.
Analog 4-20mA Output 4-20mA signal real-time feedback.
Analog 0/4-20mA Input Calibration Users can calibrate against the actual signal source at two points.
2 Relay Feedback Operation & faulty relay feedback.
Empty Tank Alarm Pump stop upon receiving a low liquid level switch signal.
Pressure Alarm Accept signal from external pressure sensors and issue an alarm upon the set value being reached.
Slow Mode Able to set 50% or 25% slow mode for dosing high viscosity media.
Discharge Calibration In addition to setting the target flow rate, users can fine-tune the flow rate output at a deeper level.
History Log Record operation and alarm.
Screen Saver Able to set screen saver after a certain delay.
Hardware
Diaphragm Rupture Alarm Optional. In the event of a diaphragm rupture, issue a signal.
Pump Head Type Optional to change pump head to hydraulic diaphragm or plunger type.
Flexible Control Panel The control panel can be installed on three sides to meet the installation requirements of different working conditions. √*

Identification Code:

Example EMG P 0150 P Q 1 E XXX
Description Pump Model Plus or Lite Flow Rate Pump Head Material Connection Method Power Supply Plug Type For Custom Make Use
Category Description
Pump Model EMM – Up to 60 L/H
EMG – Up to 200 L/H
EMA – Up to 1000 L/H
EMB – Up to 2000 L/H (First Generation Model)
Plus or Lite P – Plus Series (HMI touch screen);   L – Lite Series (Soft button + LCD Screen)
Flow Rate 0008 … 2000 – See Technical Parameters Table
Pump Head Material P – PVC                                 T – PTFE
F – PVDF                               C – SS304
S – SS316L                            D – Duplex 2205
X – Custom Make
Connection Method R – Hose Connection            S – Welding Tube
Q – PVC Socket                    F – Flange
P – RC Inner Thread             N – NPT Inner Thread
B – Barb Fitting                     X – Custom Make
Power Supply 1 – 220V 50Hz Single Phase     X – Custom Make
Plug Type A – America                               G – United Kingdom
C – China                                   I – Aus/Nz/China (Type I)
E – Europe                                N – None
X – Custom Make
Custom Make Use For factory use only. Customization options only.

WRS SMART Digital Dosing Pump – Technical Parameters:

EMM Models

EMM Models 0008 0015 0030 0060
Rated Flow Rate 8 15 30 60
Max. Discharge Pressure (Bar) 16 10 8 4
Diaphragm Size (mm) 54 54 71 71
Default Connection Method PVC Ø 6×9 PE Hose Ø 6×9 PE Hose DN15 Socket DN15 Socket
PVDF Ø 6×9 PE Hose Ø 6×9 PE Hose RC 1/2″ Inner Thread RC 1/2″ Inner Thread
SS316L Ø 6×10 Welding Tube Ø 6×10 Welding Tube Ø 10×16 Welding Tube Ø 10×16 Welding Tube
Max. Power Rating*3 (Watt) 20
Power Supply Required 220V / 50Hz / Single Phase

EMG Models

EMG Models 0060 0120 0160 0200
Rated Flow Rate (L/h) 60 120 160 200
Max. Discharge Pressure (Bar) 10 7 4 4
Diaphragm Size (mm) 71 71 112 112
Default Connection Method PVC DN15 Socket DN15 Socket DN15 Socket DN15 Socket
PVDF RC 1/2″ Inner Thread RC 1/2″ Inner Thread RC 1/2″ Inner Thread RC 1/2″ Inner Thread
SS316L Ø 10×16 Welding Tube Ø 15×22 Welding Tube Ø 15×22 Welding Tube Ø 15×22 Welding Tube
Max. Power Rating*3 (Watt) 60
Power Supply Required 220V / 50Hz / Single Phase

EMA Models

EMA Models 0375 0500 1000
Rated Flow Rate (L/h) 375 500 1000
Max. Discharge Pressure (Bar) 10 5 4
Diaphragm Size (mm) 148
Default Connection Method PVC DN25 Socket
PVDF RC 1″ Inner Thread
SS316L DN25 Welding Tube
Max. Power Rating*3 (Watt) 500
Power Supply Required 220V / 50Hz / Single Phase

EMB Models

EMB Models 1200 1600 2000
Rated Flow Rate (L/h) 1200 1600 2000
Max. Discharge Pressure (Bar) 4 3 3
Diaphragm Size (mm) 185
Default Connection Method PVC DN40 Socket
PVDF RC 1 1/2″ Inner Thread
SS316L DN40 Welding Tube
Max. Power Rating*3 (Watt) 1100
Power Supply Required 220V / 50Hz / Single Phase

Notes:
1) Test data was obtained using water at ambient temperature.
2) Only standard hose connection is included with the foot valve, PE hose, and injection valve.
3) Actual power consumption should be determined based on the application.

QUESTIONS ABOUT A TECHNICAL ISSUE? ASK OUR EXPERTS.